MOS的解释如下:
Is crossover cable supported as an interconnect with RAC on any platform. ?
NO. CROSS OVER CABLES ARE NOT SUPPORTED. The requirement is to use a switch:
Detailed Reasons:
1) cross-cabling limits the expansion of RAC to two nodes
2) cross-cabling is unstable:
a) Some NIC cards do not work properly with it. They are not able to negotiate the DTE/DCE clocking, and will thus not function. These NICS were made cheaper by assuming that the switch was going to have the clock. Unfortunately there is no way to know which NICs do not have that clock.
b) Media sense behaviour on various OS's (most notably Windows) will bring a NIC down when a cable is disconnected. Either of these issues can lead to cluster instability and lead to ORA-29740 errors (node evictions).
Due to the benefits and stability provided by a switch, and their afforability ($200 for a simple 16 port GigE switch), and the expense and time related to dealing with issues when one does not exist, this is the only supported configuration.
From a purely technology point of view Oracle does not care if the customer uses cross over cable or router or switches to deliver a message. However, we know from experience that a lot of adapters misbehave when used in a crossover configuration and cause a lot of problems for RAC. Hence we have stated on certify that we do not support crossover cables to avoid false bugs and finger pointing amongst the various parties: Oracle, Hardware vendors, Os vendors etc...
来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/15747463/viewspace-754922/,如需转载,请注明出处,否则将追究法律责任。
转载于:http://blog.itpub.net/15747463/viewspace-754922/
本文详细解释了为何Oracle RAC不支持直接使用交叉网线进行节点间连接,包括限制集群扩展到两个节点及可能引起的不稳定问题。讨论了在不同操作系统下断开连接时NIC的行为可能导致的问题,并强调了使用交换机的好处。

646

被折叠的 条评论
为什么被折叠?