. 2014 Apr 8:8:711-6.
doi: 10.2147/OPTH.S59878. eCollection 2014.

Incidence rate and occurrence of visually significant cataract formation and corneal decompensation after implantation of Verisyse/Artisan phakic intraocular lens

Affiliations

Incidence rate and occurrence of visually significant cataract formation and corneal decompensation after implantation of Verisyse/Artisan phakic intraocular lens

Majid Moshirfar et al. Clin Ophthalmol. .

Abstract

Purpose: To evaluate the incidence rate and indications for explantation of Verisyse phakic intraocular lenses (pIOLs) over a 13.6 year period.

Subjects and methods: Case series describing six cases of explantation of Verisyse pIOLs, out of 213 eyes with Verisyse pIOLs, implanted over a 13.6 year period by one surgeon at one institution, with mean follow-up of 5.6 years per eye.

Results: Four pIOLs were removed to facilitate extraction of a visually significant cataract, one was removed due to both cataract formation and development of corneal decompensation, and another was removed due to development of localized peripheral corneal decompensation. The incidence rate of pIOL removal was five per 1,000 patient-years with pIOL. Mean time from insertion of pIOL to cataract removal was 9.3 years (range 4.0-12.6 years). Mean time from insertion of pIOL to development of corneal decompensation was 10 years (range 6.9-13 years). There was no increase in the rate of cataract extraction in the pIOL population compared to the general population.

Conclusion: Cataracts may develop in patients with pIOLs, necessitating removal of the pIOL. Corneal decompensation is a serious complication that appears to be directly related to pIOLs. Corneal decompensation can occur up to 13 years following implantation of pIOLs, and long-term follow-up is important to monitor for this complication.

Keywords: Artisan lens; Verisyse lens; cataract; corneal decompensation; phakic IOL.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Slit-lamp photograph of the right eye, showing Verisyse lens implant and diffuse inferior corneal edema (case 2). Vertical enclavation was selected, because the patient had against-the-rule astigmatism, so a temporal incision would improve rather than exacerbate the astigmatism.

References

    1. Gonnermann J, Klamann MK, Maier AK, et al. Visual outcome and complications after posterior iris-claw aphakic intraocular lens implantation. J Cataract Refract Surg. 2012;38(12):2139–2143. - PubMed
    1. Güell JL, Morral M, Gris O, Gaytan J, Sisquella M, Manero F. Five-year follow-up of 399 phakic Artisan-Verisyse implantation for myopia, hyperopia and/or astigmatism. Ophthalmology. 2008;115(6):1002–1012. - PubMed
    1. Moshirfar M, Holz HA, Davis DK. Two-year follow-up of the Artisan/Verisyse iris-supported phakic intraocular lens for the correction of high myopia. J Cataract Refract Surg. 2007;33(8):1392–1397. - PubMed
    1. Stulting RD, John ME, Maloney RK, Assil KK, Arrowsmith PN, Thompson VM. Three-year results of Artisan/Verisyse phakic intraocular lens implantation. Ophthalmology. 2008;115(3):464–472. - PubMed
    1. Coullet J, Mahieu L, Malecaze F, et al. Severe endothelial cell loss following uneventful angle-supported phakic intraocular lens implantation for high myopia. J Cataract Refract Surg. 2007;33(8):1477–1481. - PubMed