Control is also a more difficult functionality to define. Control operations other than the most generic, are usually device-specific. The problem is not just a matter of providing a mechanism for control, but also defining a set of control operations which are generally applicable across a diverse set of devices. Permitting remote applications to exercise control over an entity also implies the need for a suite of safeguards to ensure that unauthorized applications cannot harm the network.
Partridge & Trewitt [Page 2]
RFC 1021 HEMS Overview October 1987
The authors settled on a system which was extensible, robust and host-architecture independent, and as simple as possible, consistent with the other goals. Extensibility was essential because it is clear that management needs will continue to evolve, and a closed system which could not be changed would be obsolete almost as soon as it was defined. Unfortunately, extensibility is also the requirement least consistent with simplicity since the need to make the system extensible led the authors to use self-describing data formats and an interpreted query language.
Partridge & Trewitt [Page 3]
RFC 1021 HEMS Overview October 1987
In the HEMS system, events are handled as slightly specialized replies to queries, and are sent to one or more management centers. Like all other HEMS messages, events are formatted in ASN.1 format.
Partridge & Trewitt [Page 4]
RFC 1021 HEMS Overview October 1987
Firefighting is a completely different situation. In this scenario, one or more sites are using management applications to try to locate and fix a network problem. Here we must assume that while the network functions (i.e., data can get through), it is not very healthy. We should assume that packets are being lost, that network routes will be non-optimal and that it is essential that the monitoring data (which is presumably diagnostic) get back to the application and that control requests are reliably delivered to the entity. In such circumstances, a reliable protocol is essential.