Network Working Group R. Hinden
Request for Comments: 1897 Ipsilon Networks
Category: Experimental J. Postel
ISI
January 1996
IPv6 Testing Address Allocation
1.0 Introduction
This document describes an allocation plan for IPv6 addresses to be used in testing IPv6 prototype software. These addresses are temporary and will be reclaimed in the future. Any IPv6 system using these addresses will have to renumber at some time in the future. These addresses will not to be routable in the Internet other than for IPv6 testing.
Hinden & Postel Experimental [Page 1]
RFC 1897 IPv6 Testing Address Allocation January 1996 2.0 Address FormatThe address format for the IPv6 test address is consistent with the provider-based unicast address allocation [PRVD] which is as follows:
| 3 | 5 bits | 16 bits | 8 | 24 bits | 8 | 64 bits | +---+----------+----------+---+------------+---+----------------+ |010|RegistryID|ProviderID|RES|SubscriberID|RES|Intra-Subscriber| +---+----------+----------+---+------------+---+----------------+The specific allocation of each field of the test address format is as follows:
| 3 | 5 bits | 16 bits | 8 | 24 bits | 8 | 16 bits|48 bits| +---+----------+----------+---+------------+---+--------+-------+ | | |Autonomous| | IPv4 | | Subnet | Intf. | |010| 11111 | System |RES| Network |RES| | | | | | Number | | Address | | Address| ID | +---+----------+----------+---+------------+---+--------+-------+where:
Hinden & Postel Experimental [Page 2]
RFC 1897 IPv6 Testing Address Allocation January 1996
The values for the autonomous system number of an organization's provider can be obtained from that provider, or can be looked up in the "whois" database maintained by the internic.net.
IPv4 Address
------------
39.11.22.1
the value to put in this field of IPv6 address is:
IPv4 Format Hex
------------ ------
39.11.22 270B16
This technique for generating values for this field only works for subscribers which have IPv4 subscriber prefixes less than equal to 24 bits long. There may be subscribers using IPv4 addresses with longer subscriber prefixes, but this conflict is expected to be very rare. Subscribers with subscriber prefixes larger than 24 bits should use the remaining bits in the IPv4 prefix as the high order bits in the Subnet Address field.
Hinden & Postel Experimental [Page 3]
RFC 1897 IPv6 Testing Address Allocation January 1996
Interface ID
4.0 References
[ARCH] Hinden, R., and S. Deering, Editors, "IP Version 6
5.0 Security Considerations
Security issues are not discussed in this memo.
6.0 Authors' Addresses
Robert M. Hinden Ipsilon Networks, Inc. 2191 E. Bayshore Road, Suite 100 Palo Alto, CA 94303 USA