GMPLS Signaling Procedure for Egress Control
1. Background
The ability to control the label used on the output/downstream interface of an egress node was one of the early requirements for GMPLS. In the initial GMPLS documents, this was called "Egress Control". As the GMPLS documents progressed, the ability to control a label on an egress interface was generalized to support control of a label on any interface. This generalization is seen in Section 6 of [RFC3471] and Section 5.1 of [RFC3473]. When this functionality was generalized, the procedures to support control of a label at the egress were also generalized. Although the result was intended to cover egress control, this intention is not clear to all. This note reiterates the procedures to cover control of a label used on an egress output/downstream interface. For context, the following is the text from the GMPLS signalling document dated June 2000 about how ERO (Explicit Route Object) for egress control:
Berger Standards Track [Page 1]
RFC 4003 GMPLS Signaling Procedure for Egress Control February 2005
6. Egress Control
2. Egress Control Procedures
This section is intended to complement Sections 5.1.1 and 5.2.1 of [RFC3473]. The procedures described in those sections are not modified. This section clarifies procedures related to the label used on an egress output/downstream interface. The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in [RFC2119].
Berger Standards Track [Page 2]
RFC 4003 GMPLS Signaling Procedure for Egress Control February 2005 2.1. ERO ProceduresEgress Control occurs when the node processing an ERO is the egress and the ERO contains one or more subobjects related to the output/downstream interface. In this case, the outgoing/downstream interface is indicated in the ERO as the last listed local interface. Note that an interface may be numbered or unnumbered.
2.2. RRO Procedures
If an ERO is used to specify outgoing interface information at the egress and label recording is indicated for the LSP, the egress should include the specified interface information and the specified label or labels in the corresponding RRO (Route Record Object).
3. Security Considerations
This document clarifies procedures defined in [RFC3473] but does not define any new procedures. As such, no new security considerations are introduced.
Berger Standards Track [Page 3]
RFC 4003 GMPLS Signaling Procedure for Egress Control February 2005 4. AcknowledgmentsValuable comments and input were received from Adrian Farrel, Alan Kullberg, and Dimitri Papadimitriou.