Network Working Group J. Burchfiel
Request for Comments: 594 BBN-TENEX
NIC: 20616 December 1973
Speedup of Host-IMP Interface
I. Introduction
In order to make the full performance capabilities of the subnet available for interprocess communication, the host's IMP interface and the IMP's host interface should operate at the highest speed obtainable.
Burchfiel [Page 1]
RFC 594 Speedup of Host-IMP Interface December 1973
Clearly, any new or retrofitted host interfaces should be very high speed, and existing host interfaces should be adjusted to operate at their maximum speed, which is in excess of 300 kilobaud.
Burchfiel [Page 2]
RFC 594 Speedup of Host-IMP Interface December 1973
Operation Byte Size Type Bandwidth User CPU seconds/Get 8 ASCII 47Kbaud 7.9 Send 8 ASCII 50Kbaud 7.9 Get 32 LocalByte 43Kbaud 1.80 Send 32 LocalByte 38Kbaud 1.70 Get 36 Image 79Kbaud 1.85 Send 36 Image 85Kbaud .95The 36-bit bandwidth of around 80Kbaud is a great improvement from the (typically 25Kbaud measured before the speedup of the interface hardware. The CPU time use has also decreased somewhat from that reported in RFC #557 by Barry Wessler: this demonstrates continued improvement of system efficiency between the TENEX version 1.31 and TENEX version 1.32.