Septic Tank & Field Clearance Distances to Water Wells
POST a QUESTION or COMMENT about the required distances or clearances between septic systems, wells, property boundaries, and other site features
Clearances or isolation distances for septic tank, drainfield, soakaway bed, & wells:
Septic tank or field setbacks & clearances for septic systems to wells, buildings, property lines, & distances to other site features. Well setbacks & clearances to septics, property lines, buildings, etc.
In this article, a detailed septic distances table describes distance requirements between septic components (septic tank, leach field, cesspools, drywells) and other site features such as wells, water supply piping, streams, trees, property boundaries, lakes, etc.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
- Daniel Friedman, Publisher/Editor/Author - See WHO ARE WE?
Online Tables of Required Septic Setbacks & Clearance Distances
In general, septic effluent must be disposed of on the property from which it originates.
However stricter clearances and distances than this are required between various onsite wastewater treatment system components and buildings, property boundaries,
lakes, streams, wells, and so on, as detailed in the table below. Contact us with corrections or additions to this data.
Photo above: this is what happens when you dig down to install a swimming pool too close to the septic drainfield.
These septic component clearance distance tables below give distance requirements between septic components and wells, streams, trees, property boundaries, lakes, etc.
Common guidelines require at least 50' clearance distance between a well and a septic system tank or 150' between
a well and a septic drainfield or leaching bed but you will see that different authorities may recommend different distances.
Local soil and rock conditions can make these "rules of thumb" unreliable. See "One and Two Family Dwelling Code, Section P-2510-Combined Seepage Pits and Disposal Fields," and Table P-2504, "Location of Sewage Disposal System." Other references are cited at the end of this table.
Note that clearance distances from any septic system component such as septic effluent line tank to D-box and
particularly including the drainfield, leachfield, soakaway, soakbed,
or other synonyms for sewage effluent disposal will vary additionally in some jurisdictions according to 8-1
- The soil type. Rocky or sandy soils require greater setback distances from well to septic
- The soil grade or slope and location of a water well that is down-slope from the septic system,
e.g. if the wastewater treatment system is up-slope from and in direct path of surface water drainage towards a well, the closest part of the septic system must be at least 200' away from the well.
Well separation distances from contaminant sources are increased by 50% whenever aquifer water enters the water well at less than 50 ft. below grade or additional measures to prevent contamination must be added.
Distances for these onsite wastewater treatment components are given in feet to other site features unless otherwise stated
(a few distances may be given in inches).
Numbers in bold-face are those more-widely accepted or most inquired by our readers.
Variations: These septic information tables give typical required clearances for septic tank, soil absorption system (SAS), etc. but you will see that different authorities may recommend different distances.
Small residential sewage treatment plant clearance distances are typically the same as those given for septic tanks.
Conventional Designs:
These distances are for conventional onsite waste disposal systems which specify clearances presuming that effluent is being disposed of after minimal treatment such as is received by a septic tank or cesspool.
Advanced onsite
wastewater treatment systems, such as those described by Jantrania and Gross (2006), permit substantial reduction in these clearances, depending on the level of treatment achieved.
Crossings
of subsoil drains, lakes, watercourses, streams, wetlands, and dry gulches may be permitted where pipelines are constructed of sufficient strength to contain flows under pressure, based on Colorado septic setbacks as cited below.
Drainfield clearance distances
are typically measured as from the site feature to the nearest edge of the drainfield area or trench, soak-pit, soakaway bed, mound, or raised bed, depending on septic design type. "Septic Setbacks - minimum separation distances, Park County CO, retrieved 2016/03/31, original source: http://www.parkco.us/DocumentCenter/Home/View/348
200 ft. The distance of 200 feet shall be maintained where fractured or jointed bedrock is within 7 ft. of the surface unless the results of a sub surface soil and geological investigation conducted by a professional
geologist indicates that a lesser distance would not result in contamination of adjacent wells or aquifers. - [CO]
Add 8 ft. additional distance for each 100 gallons per day design flow over 1000 gallons per day as specified in the table unless it can be demonstrated by a professional engineer or geologist that a
mechanical or natural barrier will prevent contamination. [CO]
Crossings may be permitted where pipelines are constructed of sufficient strength to contain flows under pressure. [CO]
The minimum distance required between wells and leach fields in subdivisions and all other developments, platted after January 1, 1997, shall be 200 feet. [CO]
Abbreviations:
SAS = Soil Absorption System - Leach Field etc.
UPC = Uniform Plumbing Code
Sources
of example septic setback & clearance distances, codes, citations, authorities
CO = Colorado septic setbacks, see PARK COUNTY, COLORADO ON-SITE WASTEWATER TREATMENT SYSTEM REGULATION [PDF] (2018) , Park County CO, retrieved 2016/03/31, original source: www.parkco.us/DocumentCenter/Home/View/348 - dead link in 2023, New Link - retrieved 2023/-08/28 original source: parkco.us/DocumentCenter/View/1628/Park-County-On-Site-Wastewater-Treatment-System-Regulations?bidId=
EPA references above and for other EPA information see WATER WELL CONSTRUCTION & MAINTENANCE [Web article - Details to Help Avoid Well Water Contamination] US EPA
Mass.Title5 = Massachusetts Title 5 Septic Code
FL = Florida septic component clearances table, also see Florida 64E-6.005 Location and Installation. (2013)
General or "typical" septic component clearance distances are based on the CO information source where available
MA = Massachusetts septic component clearances table. See also the NY table Appendix 75 given below.
MO = Missouri SEPTIC COMPONENT CLEARANCE DISTANCES [PDF] [Excerpted from the document cited just below] - Missouri distances and septic lagoon system clearances to other site features
University of Missouri extension.
For Missouri, Table 1 in this document shows the minimum setback distances that must be observed for septic tanks and absorption fields.Â
MO - Schulthesis, Robert A., Missouri SEPTIC TANK & ABSORPTION FIELD HOMEOWNERS GUIDE [PDF] (2001) retrieved 2022/04/25 original source: extension.missouri.edu/publications/eq401-dead link; valid updated link 2023/08/28: extension.missouri.edu/publications/eq401
NY = New York State septic component clearances table New York State Department of Health, APPENDIX 75-A WASTEWATER TREATMENT STANDARDS - INDIVIDUAL HOUSEHOLD SYSTEMS , [PDF] (2010) New York State Department of Health, 3 February 2010, retrieved 3/1/2010, original source: https://www.health.ny.gov/regulations/nycrr/title_10/part_75/appendix_75-a.htm
Unofficial compliation of codes, rules and regulations of the state of
New York Title 10. Department of Health. Chapter ii. Part 75. Standards for
Individual onsite water supply and individual onsite wastewater
treatment systems. Appendix 75-a.
US HUD -1 Distance from source of pollution - proposed construction, US Dept. of Housing and Urban Development, FHA, Local acceptable standard No. 3, June 18, 1992, Ref. Hud Handbook 4910.1 Chg 1, Appendix K, Pg K-27
Distances for these onsite wastewater treatment components are given in feet to other site features unless otherwise stated
(a few distances may be given in inches).
These septic information tables give typical required clearances for septic tank, soil absorption system (SAS), etc. but you will see that different authorities may recommend different distances.
Small residential sewage treatment plant clearance distances are typically the same as those given for septic tanks.
These distances are
for conventional onsite waste disposal systems which specify clearances presuming that effluent is being disposed of after minimal treatment such as is received by a septic tank or cesspool. Advanced onsite
wastewater treatment systems, such as those described by Jantrania and Gross (2006), permit substantial reduction in these clearances, depending on the level of treatment achieved.
Crossings
of subsoil drains, lakes, watercourses, streams, wetlands, and dry gulches may be permitted where pipelines are constructed of sufficient strength to contain flows under pressure, based on Colorado septic setbacks as cited below.
Drainfield clearance distances
are typically measured as from the site feature to the nearest edge of the drainfield area or trench, soak-pit, soakaway bed, mound, or raised bed, depending on septic design type. "Septic Setbacks - minimum separation distances, Park County CO, retrieved 2016/03/31, original source: http://www.parkco.us/DocumentCenter/Home/View/348
200 ft. The distance of 200 feet shall be maintained where fractured or jointed bedrock is within 7 ft. of the surface unless the results of a sub surface soil and geological investigation conducted by a professional
geologist indicates that a lesser distance would not result in contamination of adjacent wells or aquifers. - [CO]
Add 8 ft. additional distance for each 100 gallons per day design flow over 1000 gallons per day as specified in the table unless it can be demonstrated by a professional engineer or geologist that a
mechanical or natural barrier will prevent contamination. [CO]
Crossings may be permitted where pipelines are constructed of sufficient strength to contain flows under pressure. [CO]
The minimum distance required between wells and leach fields in subdivisions and all other developments, platted after January 1, 1997, shall be 200 feet. [CO]
Sources of example septic setback & clearance distances, codes, citations, authorities
CA = California septic system codes including this model: CA GLENN COUNTY CALIFORNIA SEWAGE DISPOSAL CODE [PDF] - this is a 2.3MB PDF file retrieved 2017/05/08, original source https://www.countyofglenn.net/sites/default/files/Environmental_Health/SewageDisposalRegulations.pdf
CO = Colorado septic setbacks, see "Septic Setbacks - minimum separation distances, Park County CO, retrieved 2016/03/31, original source: http://www.parkco.us/DocumentCenter/Home/View/348
FL = Florida septic component clearances table, also see Florida 64E-6.005 Location and Installation. (2013)
General or "typical" septic component clearance distances are based on the CO information source where available
MA = Massachusetts septic component clearances table
MO = Missouri septic component clearances table - Missouri distances and septic lagoon system clearances to other site features University of Missouri extension lagoon web page muextension.missouri.edu/explore/envqual/wq0402.htm
NY = New York State septic component clearances table
New York State Department of Health, NY APPENDIX 75-A WASTEWATER TREATMENT STANDARDS - INDIVIDUAL HOUSEHOLD SYSTEMS [PDF] New York State Department of Health, 3 February 2010, retrieved 3/1/2010, original source: https://www.health.ny.gov/regulations/nycrr/title_10/part_75/appendix_75-a.htm
US HUD -1 Distance from source of pollution - proposed construction, US Dept. of Housing and Urban Development, FHA, Local acceptable standard No. 3, June 18, 1992, Ref. Hud Handbook 4910.1 Chg 1, Appendix K, Pg K-27
NC NORTH CAROLINA SEPTIC SETBACKS & CODE [PDF]
retrieved 2018/03/17, original source: alamance-nc.com/envhealth/wp-content/uploads/sites/9/2013/10/SepticRulesCompleteEff10012011.pdf CHAPTER 18 - ENVIRONMENTAL HEALTH SUBCHAPTER 18A - SANITATION SECTION .1900 - SEWAGE TREATMENT AND DISPOSAL SYSTEMS
In this document see 15A NCAC 18A .1950 LOCATION OF SANITARY SEWAGE SYSTEMS
NC CONVENTIONAL SEPTIC SYSTEMS in NORTH CAROLINA [PDF] Rule .1955 15A NCAC 18A .1900
Laws and Rules for Sewage Treatment and
Disposal Systems, North Carolina Department of Public Health, retrieved 2018/03/17, original source: ehs.ncpublichealth.com/oet/docs/cit/oswpmod/oswt/C-ComponentsofConventionalSystem.pdf
NOTICE: this is a presentation and does not include actual North Carolina septic code specifications, setbacks, distances.
Also see https://content.ces.ncsu.edu/septic-systems-and-their-maintenance that in turn cites
Mancl, K.M. 1984. Journal of Environmental Engineering, Vol. 110(1):283â285 and omits North Carolina septic code details.
The below listed minimum separation distances as stipulated in North Carolina General Statutes 130A-335 (e),
(f), are the most commonly used in planning for a home or small business.
North Carolina Septic Tank Clearance distances:
septic tanks cannot be placed where there may be flooding every 10 years or less, unless the septic tank is watertight, anchored, and storm-water-entry-proof
at least 5 ft. from any building foundation
at least 10 feet away from property lines, water lines, and the up-slope portion of drainage systems
at least 15 feet between septic tanks and basements, embankments, drainage system side-slopes, and swimming pools
at least 25 ft. from property line
at least 25 feet setback for groundwater lowering ditches and devices, and the down-slope of drainage systems
at least 50 feet from any lake or pond
at least 100 feet away from private or public water supplies, streams, and reservoir
Table 3 Septic Component Clearance Distances to a Water Well According to Soil Type & Septic System Type
Soil Conditions 1
Depth from SAS Bottom to Groundwater Seasonal High Level 2
Septic Filter Trench Type & Distances to Water Well in Feet
Comments
TYPE I
Gravity-fed @ Normal Loading 3
TYPE II
Pressure-Dosed @ Normal Loading 3
TYPE III Pressure-Dosed @ Low-Loading 4
Very coarse gravelly soil < 5% Fines5
4 to 5 ft.
Not Allowed
200 ft.
150 ft.
Soil properties in other geographic locations and in other sewage code jurisdictions will differ and may have different allowable septic system clearance distances than our examples given here.
> 5 ft to 10 ft
200 ft.
150 ft.
100 ft.
> 10 ft.
150 ft.
100 ft.
100 ft.
Coarse sandy soil, 5 to 15% Fines
4 to 5 ft.
200 ft.
150 ft.
100 ft.
> 5 ft to 10 ft
150 ft.
100 ft.
100 ft.
> 10 ft.
100 ft.
100 ft.
100 ft.
Notes to the Table Above & Sources of Example Septic System Codes & Specifications
Here "soil" is defined as the "predominant" soil between the bottom of the trench (rock bed) and the uppermost level reached by seasonal high-water in the soils below.
Also, the soil must be both well-graded and having at least 40% of the soil passing a #4 sieve test (5mm sieve test).
These distances are from bottom of the soil absorption system trench to the top of seasonal high groundwater table (see also Massachusetts Title 5 Septic Code). Any septic effluent disposal or absorption field that is seasonally flooded cannot work and cannot meet these specifications.
"Normal septic system loading" rate is defined as a soil application rate of effluent at 1.0 gallons per day per linear foot of trench along the bottom area of the trench.
"Low septic system loading" rate is defined as a soil application rate of sewage effluent at 0.5 gallons per day per linear foot of trench along the bottom area of the trench.
Definition of soil fines: the portion of soil particles whose size is smaller or "finer" than particles passing through a No. 200 sieve (0.075 mm) .
Note that for some purposes and in some jurisdictions a second definition of soil fines uses a No. 400 sieve (0.038mm), for example in discussions of soil liquefaction resistance - not a common factor in septic system design.
CA = California septic system codes including this model: CA GLENN COUNTY CALIFORNIA SEWAGE DISPOSAL CODE [PDF] - 2.3MB PDF retrieved 2017/05/08, original source https://www.countyofglenn.net/sites/default/files/Environmental_Health/SewageDisposalRegulations.pdf
When wastewater treatment systems are located upgrade and in the direct path of surface water drainage to a well,
the closest part of the treatment system shall be at least 200 feet away from the well.
Mean high water mark.
For all systems involving the placement of fill material, separation distances are measured from the toe of the slope
of the fill.
Separation distances shall also be measured from the edge of the designated additional usable area as described in
Section 75-A.4 (a)(5).
The closest part of the wastewater treatment system shall be located at least 10 feet from any water service line (e.g.
public water supply main, public water service line or residential well water service line).
When sand filters are designed to be watertight and collect all effluent, the separation distance can be reduced to 50
feet.
The listed water well separation distances from contaminant sources shall be increased by 50% whenever aquifer
water enters the water well at less than 50 feet below grade.
If a 50% increase cannot be achieved, then the greatest
possible increase in separation distance shall be provided with such additional measures as needed to prevent
contamination.
...
ADVERTISEMENT
Reader Comments, Questions & Answers About The Article Above
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
What's the minimum distance required between a sewage holding tank and a garage?
How close can you build a garage to a holding tank. And does a holding tank have a septic field in most cases or no ? On 2022-06-06 by Alice A Smith
by InspectApedia-911 (mod)
@Alice A Smith,
Septic tank distance to a structure isn't given uniformly across jurisdictions (you don't specify country, city, province, state &c.) but is typically 10 ft.
A holding tank is just that: it "holds" or "stores" wastewater. It does not let anything out. The holding tank has to be emptied by a septic pumping contractor.
Holding tanks are prohibited (illegal) in nearly all jurisdictions except by special permit, such as perhaps a restaurant built along the edge of a river or stream.
What's the necessary clearance distance from garage to leachfield ?
I want to build a garage above ground. How far does it need to be from the leech area of septic system? On 2020-06-12 by john Herod
by (mod) -
John
The clearance distance between your garage walls and drive to it need to be (typically) 5 ft to 20 ft. depending on local codes where you live. Most states in the U.S. want 20 ft. but some permit much closer clearances.
Watch out: even if you meet the garage setback to septic drainfield, be sure that your builder, in the course of putting up the garage, doesn't drive equipment over the leachfield or it may be damaged or ruined.
How do we make the separation distance measurements between a septic mound and a swimming pool?
We Are installing an above ground pool. We want to measure the distance from the mound to the pool to make sure weâre in compliance. What are the two points from which we measure On 2022-04-13
by Denise ryan
Just above is our (DF) Photograph of a swimming pool installed too close to a septic drainfield - in failure
by Inspectapedia Com Moderator (mod) - installing an above ground pool
@Denise ryan,
You measure the closest point of pool or any pool equipment to the closest bottom edge of the septic mound.
But there's more to consider. Be sure that the contractor building the pool doesn't drive equipment over the mound as that will damage it.
And be sure that any swimming pool discharge, such as when you are backwashing the filter or emptying the pool, is directed away from the mound.
Why does a potable water pipeline have to be distant from the septic fields?
Why do they say that a potable water supply line should be 10-25 feet from a septic drain field? Is is because the water pipe may break and flood the drain field? On 2022-02-16 by Raquel B
by Inspectapedia Com Moderator (mod) - potable water supply line should be 10-25 feet from a septic drain field
@Raquel B,
More likely the concern is that a leak in supply piping combined with a temporary loss of pressure or even exposure during its installation risks contamination of the water supply, poisoning or sickening building occupants.
How do we measure the right distance between septic mound and private water well?
The setback of a mound from a private well is measured from _______ of the mound? Is it the highest point can't seem to find a answer - On 2021-12-22 by Bigzasty@yahoo.com
by Inspectapedia Com Moderator - private well distance to mound: measure from toe of the mound-fill
@Bigzasty,
Clearance distances are typically measured from the site feature (the private well in your case) to the nearest edge of the toe or edge of fill that was used to construct the mound or raised-bed septic drainfield area or trench, soak-pit, soakaway bed, MOUND, or raised bed.
What that clearance distance will need to be are defined in the tables above on this page and depend on various factors such soil type and septic system type.
How far from my soils tank (septic tank) will I findthe drainfield?
i found the drain tank or leach field for water what would the distance be to the soils tank On 2020-12-13 by kelly sims
by (mod) - septic drainfield distance to septic tank soils tank
Kelly
There is no fixed dor standard istance involved and the location as well as distance world pretty much always be site dependent. However if you found any component of the septic system your plumber can insert a sewer line camera or other grain locating equipment in order to follow the lines to the septic tank or distribution box
What's the usual septic distance to the septic D-box
Normal distance from septic to D box in NK RI On 2020-11-28 by Jim
Reply by (mod) -
The distance from the tank to the D boxes site dependent but typically is 10 to 75 feet
How far should we keep the septic leachfield from a cemetery?
Any recommendations on appropriate distance for a leachfield from an already established cemetery on the same property? On 2020-07-19 by Carol
by (mod) -
Carol
Thank you for an interesting question.
I doubt that there is a single "right answer" to separation distance of septic drainfields or leachfields and cemeteries as there are quite a few variables such as terrain shape, soil properties, cemetery activity.
What problem are we avoiding: the obvious one at first glance might simply be avoiding any risk of sewage effluent showing up in an excavation for a grave. To be totally safe you'd use the same setbacks as for a well or water source. Typically that's 100 ft. or more.
by Carol
Yikes--not sure we have that much space. But yes, that's the biggest concern. So, thanks.
What's the well distance to septic for a VA Loan?
How far does the well have to be from the septic system for a VA loan qualification. On 2020-05-20 by billieallen
by (mod) -
BillieAllen:
In the U.S. the VA has not specified setbacks between well and septic; but the property certainly should meet your local and state requirements.
Those vary a bit depending on the property location, but 100 feet separation between well and septic is reasonable.
What's the recommended distance of a buried propane tank to a septic drainfield
How close can an in-ground 250 gal propane tank be buried to a septic drain field? On 2020-03-06 by Mark Berger
by (mod) -
Mark
I don't think we'll find a septic nor propane tank code that addresses the distance relationships between those two systems, but it would make sense to
1. be dead sure that nobody drives heavy equipment over your drainfield
2. keep excavation for the buried propane tank far enough away from the drainfield that you won't disturb the drainfield by the excavation, installation, soil piles, backfilling, trenching for buried gas lines, etc.
What's the required shed distance to aerobic septic system spray heads?
How far does a shed have to be from aerobic spray heads ? On 2020-02-02 by Jim
by (mod) -
OPINION:
Jim,
The footprint of the shed ought not be in the spray area at all;
Beyond that it needs to be far enough away so as not to be sprayed.
Does the depth of well (100 foot deep well) affect required distance from my septic tank ?
How far does a 100 foot deep well have to be from my septic tank ? On 2020-01-14 by bob dubois
Bob
you're on the correct web page, and the well clearance distances to septic are given above. The well depth doesn't change that General guideline.
however one could infer an important point from your question. That is one might think that a deeper well is indeed less likely to suffer contamination from a source close to the ground surface, such as a drain field for septic tank. However I think without extremely specific site to tell that's not something you can count on.
A lot depends on the Underground soil conditions, Rock, local water tables Etc.
In addition to any citations in the article above, a full list is available on request.
Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross. Anish Jantrania, Ph.D., P.E., M.B.A., is a Consulting Engineer, in Mechanicsville VA, 804-550-0389 (2006). Outstanding technical reference especially on alternative septic system design alternatives. Written for designers and engineers, this book is not at all easy going for homeowners but is a text I recommend for professionals--DF.